Sika Sikament-100 SC

Sikament-100 SC minimizes or eliminates dewatering requirements at underwater construction sites prior to concrete placement. Concrete can be pumped or placed via tremie directly into water-covered areas. Sikament-100 SC preserves concrete matrix integrity during high-slump placements and prevents washout from surfaces during curing.

  • Minimizes or eliminates dewatering expenses related to underwater construction
  • Concrete pumps easily and flows smoothly into available spaces
  • Reduces segregation and dilution while significantly improving in-place compressive and bond strength

Sikament-100 SC Datasheet

Contact Us to Order Call to Order

Sikament-100 SC is a precision-engineered bipolymer anti-washout admixture designed to revolutionize underwater concrete and grout placement in both fresh and saltwater environments. This unique formulation meets CRD-C661-06 requirements and delivers exceptional cohesiveness through its variable viscosity technology. When mechanically agitated or sheared during pumping operations, the concrete becomes fluid and highly flowable, enabling easy placement through confined spaces and complex geometries without costly dewatering procedures.

The admixture’s innovative bipolymer chemistry transforms concrete behavior by creating a dense, high-viscosity consistency when at rest, while maintaining excellent pumpability during placement. This dual-action characteristic ensures superior underwater “stacking” performance during tremie operations and dramatically improves concrete’s ability to penetrate and consolidate foundation rock layers in challenging marine construction projects. At a dosage rate of approximately 0.5 gallons per cubic yard, Sikament-100 SC doubles the active slump life without extending setting times, making it an essential solution for contractors facing underwater construction challenges.

✨ Looking for a different product?

We’re here to answer all of your questions about cement grout, or any of the other products we carry.

Contact Us

Key Features of Sikament-100 SC

Variable Viscosity Technology
Becomes fluid when sheared or agitated during pumping, then reverts to high-viscosity state at rest for superior underwater placement control.

Eliminates Dewatering Costs
Allows direct concrete placement into water-covered areas by pump or tremie, reducing or eliminating expensive dewatering operations.

Enhanced Matrix Integrity
Maintains concrete cohesiveness during high slump placements and significantly reduces washout from surfaces during curing.

Superior Flow Characteristics
Concrete flows readily into available spaces while preventing segregation and dilution for increased in-place strength.

Extended Workability
Doubles the active slump life of concrete without causing delays in setting time, improving construction efficiency.

Reduced Laitance Formation
Minimizes or eliminates cement paste washout during curing, resulting in superior surface quality and bond strength.

Recommended Applications for Sikament-100 SC

Sikament-100 SC is engineered for marine contractors and engineers who need reliable underwater concrete placement without the complexity and cost of dewatering operations. Its unique chemistry makes it particularly valuable for foundation work, pier construction, and repair projects where concrete must maintain integrity while placed directly into aquatic environments.

Ideal Applications Include:

  • Underwater concrete placement in fresh and saltwater environments 
  • Tremie concrete operations for improved “stacking” characteristics
  • Foundation rock layer penetration and consolidation 
  • Jetty sealing and marine structure construction 
  • Concrete placement into bentonite slurries 
  • Bridge pier and abutment construction 
  • Underwater repair and rehabilitation projects 
  • Marine infrastructure maintenance

🌊

Technical Specifications – Sikament-100 SC

Anti-washout bipolymer admixture with comprehensive performance data for underwater concrete and grout placement.

🌊
CRD-C661-06 Compliant
📦
0.5 gal/yd³ Dosage Rate
⚖️
1.22 Specific Gravity
📅
1 Year Shelf Life

Product Information: Anti-washout bipolymer admixture for underwater concrete placement
Property Value Details
Appearance/Color Brown Liquid Ready-to-use admixture
Specific Gravity Approx. 1.22 At standard conditions
Storage Temperature Above 40°F (5°C) Thaw and agitate if frozen
Shelf Life 1 Year 50-80°F (10-27°C) storage

Application Information: Dosage and mixing requirements for optimal underwater performance
Parameter Specification Notes
Recommended Dosage 0.5 gal/yd³ (10 fl.oz. / #100 cwt.)
Cement Content Basis 660 lbs 0.40 W/C ratio
Mixing Sequence Add Last After all ingredients blended
Standards Compliance CRD-C661-06 Anti-washout requirements

Packaging Options: Multiple container sizes available for project requirements
Package Size Volume (US) Volume (Metric)
Pail 5 gallon 19 liter
Drum 55 gallon 208 liter
Bulk Delivery Available Contact for details


Underwater Placement Ready

Fresh & Saltwater Compatible

Bipolymer Technology

Variable Viscosity Control

Tremie & Pump Compatible

Reduces Laitance Formation
Professional Application: Add to concrete after all other ingredients are blended. Use turbine mixers or central mix plants for best results. Consult a sales representative for project-specific guidance.

Frequently Asked Questions

What is the recommended dosage rate for Sikament-100 SC?
The standard dosage is approximately 0.5 gallons per cubic yard (10 fl.oz. per 100 cwt.) based on 660 lbs. of cement with a 0.40 water-cement ratio. Dosage must be proportionately increased when water content increases.

How should Sikament-100 SC be added to the concrete mix?
Add the admixture to fresh concrete after all other mix ingredients have been thoroughly blended together. Adding too early in the mixing process may cause clumping of materials.

What mixing equipment works best with this admixture?
Turbine mixers and central mix plants typically perform better than dry batched transit mixers. The concrete mixer must be capable of thoroughly shearing materials and blending all components for optimal results.

What are the storage requirements?
Store above 40°F (5°C). If frozen, thaw completely and agitate thoroughly before use. Shelf life is one year when stored in dry warehouse conditions between 50-80°F (10-27°C).

Can higher dosages be used for enhanced performance?
Higher dosages may delay the initial concrete set. Additional high range water reducing admixtures may be required to obtain desired workability. Consult your local Sika representative for guidance.

What happens if insufficient quantities are used?
Using less than recommended quantities or insufficient mixing may result in concrete that is more likely to bleed or separate during underwater placement.

🔧